Shin Huat Trading & Engineering Sdn. Bhd. supplies DI fire hydrants in Penang for commercial, industrial, building services and infrastructure fire protection applications.
A DI Fire Hydrant, also known as a Ductile Iron Pillar Hydrant, provides firefighters with fast access to a pressurised water supply during fire emergencies. The hydrant is designed for installation as part of an external fire fighting water distribution system.
The DN100 pillar hydrant is commonly supplied with a ductile iron body, dual 2½-inch outlets and DN100 / 4-inch flanged inlet. PN16 configurations and different outlet, flange and coating specifications are available depending on the selected model and project requirements.
Suitable for factories, warehouses, commercial buildings, industrial facilities, residential developments, infrastructure projects and external fire fighting water networks.
Based in Penang, Shin Huat Trading & Engineering supplies fire fighting equipment and engineering products for projects in Penang, Butterworth, Seberang Perai and surrounding areas. Contact our team with your required quantity and technical specification for product availability and quotation.
Product specifications may vary according to brand, model, stock availability and project requirements. Please contact us for technical confirmation before ordering.
DI Fire Hydrant DN100 ductile iron pillar hydrant. Actual product appearance may vary according to brand and model.A professional ductile iron pillar hydrant designed to provide access to a pressurised fire water supply for commercial, industrial, infrastructure, building services and external fire protection systems.
A DI Fire Hydrant provides a controlled connection point to a pressurised fire water network, allowing firefighting hoses to be connected when water is required for fire protection operations. A typical DN100 configuration uses a 4-inch flanged inlet connected to the underground or external fire water supply system.
Applicable models may use a common 2-way outlet arrangement with two 2½-inch outlets. These hydrants are used across commercial buildings, factories, industrial facilities, infrastructure projects, residential developments and other external fire protection applications. Final specifications should always be checked against the selected brand, model and project requirements.
Core product characteristics based on available DN100 ductile iron pillar hydrant configurations.
Durable ductile iron construction suitable for fire fighting applications and external fire water systems.
Applicable models are available with two 2½-inch outlets for connection to firefighting hoses.
PN16 configurations are available depending on brand and model, with final pressure requirements subject to confirmation.
Reference models use a DN100 / 4-inch flanged inlet for connection to the fire water supply network.
Red or yellow finishes are available, with gloss paint or epoxy coating depending on the selected model.
Suitable for commercial, industrial, infrastructure, building services and external fire protection applications.
Reference specifications compiled from available DI fire hydrant models. Values that differ between models are clearly identified.
| Product Type | Ductile Iron Pillar Fire Hydrant |
|---|---|
| Nominal Size | DN100 / 4 inch |
| Body Material | Ductile Iron |
| Body Standard | BS 1563 / BS 2789 depending on model |
| Outlet Material | Copper Alloy / Gunmetal |
| Outlet Standard | BS 1982 / BS 1400 depending on model |
| Outlet Grade | LG2 available depending on model |
| Outlet Configuration | 2 × 2½ inch outlets |
| Outlet Connection | Female BS Instantaneous Outlet / threaded outlet depending on model |
| Inlet | DN100 / 4 inch Flanged Inlet |
| Flange Standard | BS 10 Table E / BS 4772 / BS 4504 depending on model |
| Nominal Pressure | PN16 |
| Working Pressure | Up to 15 bar depending on model |
| Test Pressure | Up to 20 bar depending on model. Selected models may have different testing requirements. |
| Flow Test | Above 2,000 litres/minute at 1.7 bar for applicable model |
| Finish | Red or Yellow |
| Coating | Gloss Paint / Epoxy Coating Available |
Reference dimensions from an applicable DN100 DI hydrant model.
| Overall Height (H) | 827 mm |
|---|---|
| W1 | 130 mm |
| W2 | 102 mm |
| Outlet Internal Diameter | 64 mm |
| Outlet External Diameter | 75 mm |
| Outlet Length | 122 mm |
Dimensions shown are reference values from an applicable DN100 DI hydrant model and may vary between manufacturers.
Common project environments where DI pillar hydrants may form part of the external fire protection or fire water supply system.
Shin Huat Trading & Engineering Sdn. Bhd. supplies DI fire hydrants and fire fighting equipment for commercial, industrial and infrastructure projects in Penang, Butterworth, Seberang Perai and surrounding areas. Contact our team with your required quantity and technical specifications for product availability and quotation.
Common questions about DI Fire Hydrants, specifications, applications and quotation requests.
Send us your quantity and required specification. Our team will help you check product availability, technical requirements and provide the best available quotation.
Best Price Quote